Designed the L-shaped enclosure that holds the cell block and all HV and LV components: 2 main and 2 precharge contactors, 2 precharge resistors, the fuse, BMS, sense boards, DC-DC converter and 6 MPPTs
Sized the cooling and ventilation and checked the design against the ASC 2026 regulations (Rev C)
Mounted the parts in layers on G10 plates with standoffs (non-conductive, stiff, lighter than aluminum), so any plate can be removed alone. The envelope was 186 mm inner width and a 286 mm height limit.
Split the HV parts onto HV+ and HV- plates, each at its own pack terminal, for short cables, separated poles and isolation on both sides. The MPPTs went in as 4 flat and 2 upright.
Sized the cooling by hand: 90 W of MPPT heat at a 15 K air rise needs about 11 CFM. Chose two stacked 92 mm exhaust fans (20 to 25 CFM) and a 120 x 80 mm louvered vent at mid cell height.
Checked mass, height and interference in Siemens NX
Highest part at 251 mm against the 286 mm limit
About 2x airflow margin over the 90 W heat load
Met the energy, enclosure, cooling, fuse, contactor, cell-tap and BMS protection requirements, with each one mapped to its ASC clause
Recommended replacing the G10 plates with CFRP plates that have an insulating skin, estimated at about 40% lighter plates. This is a proposal that still needs a hipot test, and it has not been built or tested.