Built a complete equivalent circuit (OCV-R) model for an NMC 18650 cell: current integration, SOC tracking, and terminal voltage prediction
Characterized voltage behavior across three C-rates, a pulse current profile, and three constant-power discharge levels
Built in overcharge/overdischarge protection logic that halts the model when safety bounds are violated
Implemented the model in MATLAB/Simulink as dz/dt = -I/Qmax with Vt = OCV(z) - IR, using Qmax = 5.2 Ah, R = 0.009 Ω
Added overcharge (>3.6V) and overdischarge (<3.15V) cutoffs wired through comparator logic to a stop condition
Simulated constant-current discharge at 0.4C, 1C, and 2C to isolate the resistive (IR) contribution from the SOC-dependent OCV baseline
Simulated a repeating pulse current profile (5A charge / 1A discharge, 20s each, from SOC = 0.5) to capture transient voltage response
Derived discharge current as a function of demanded power and terminal voltage by solving P = I·Vt as a quadratic in I
Implemented the power-driven current relationship in Simulink so current self-adjusts as terminal voltage sags, then simulated constant-power discharge at 5W, 15W, and 25W
Delivered a working OCV-R model validated across constant-current, pulse, and constant-power operating modes
Discharge time scales inversely with C-rate, from roughly 9000s at 0.4C to roughly 1800s at 2C, with proportionally larger voltage sag at higher rates
Cleanly separated the resistive voltage drop from the OCV baseline, both in steady discharge and under pulsed loading
Derived and implemented I = [OCV(z) − √(OCV(z)² − 4RP)] / (2R) for constant-power discharge
Higher power levels reach the voltage cutoff far sooner: roughly 2300s at 25W vs. roughly 12500s at 5W